Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	69
Date	08/12/14
Start Time	11:50:00
Diameter Midpoint
 10.9	20643.6
 11.3	248182
 11.8	448190
 12.2	325547
 12.6	272355
 13.1	236214
 13.6	196858
 14.1	161803
 14.6	124531
 15.1	93779.3
 15.7	66881.4
 16.3	46343.4
 16.8	31730.9
 17.5	18565.2
 18.1	11585.9
 18.8	7215.11
 19.5	4383.37
 20.2	3058.88
 20.9	1848.37
 21.7	1371.58
 22.5	1263.24
 23.3	1576.75
 24.1	2132.69
 25.0	3466.59
 25.9	4354.16
 26.9	5646.33
 27.9	7416.56
 28.9	7999.02
 30.0	8314.46
 31.1	7892.3
 32.2	6795.83
 33.4	5261.65
 34.6	4480.61
 35.9	3493.94
 37.2	2521.29
 38.5	2006.54
 40.0	1560.6
 41.4	932.556
 42.9	686.765
 44.5	491.769
 46.1	532.674
 47.8	741.041
 49.6	1766.36
 51.4	3764.75
 53.3	5774.73
 55.2	7433.82
 57.3	7577.95
 59.4	7678.76
 61.5	7075.64
 63.8	6361.86
 66.1	5520.09
 68.5	4806.35
 71.0	4032.6
 73.7	3418.42
 76.4	2845.57
 79.1	2090.56
 82.0	1588.65
 85.1	1282.57
 88.2	889.39
 91.4	652.974
 94.7	502.435
 98.2	391.197
101.8	303.89
105.5	245.952
109.4	321.644
113.4	323.425
117.6	331.29
121.9	321.375
126.3	328.386
131.0	291.735
135.8	225.114
140.7	182.105
145.9	195.871
151.2	158.512
156.8	102.938
162.5	90.5912
168.5	53.0584
174.7	56.3795
181.1	41.3722
187.7	27.7091
194.6	32.187
201.7	18.0112
209.1	28.9162
216.7	29.9197
224.7	12.3188
232.9	4.91849
241.4	22.8165
250.3	11.648
259.5	10.5837
269.0	7.38125
278.8	5.13744
289.0	18.427
299.6	10.84
310.6	9.46514
322.0	6.22624
333.8	10.5512
346.0	0
358.7	4.8834
371.8	6.07591
385.4	4.49842
399.5	4.99197
414.2	8.82817
429.4	2.36348
445.1	9.57467
461.4	4.88268
478.3	6.42695
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1585
High Voltage	9880.7
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	12.741
Mean(nm)	15.3326
Geo. Mean(nm)	14.0036
Mode(nm)	11.7574
Geo. Std. Dev.	1.40469
Total Concentration(#/cm)	2.48e+006
Comment	